Farm CHP | Cogeneration
biogas_cogeneration_gensets_CHP_Combined_Heat_and_Power_PICT0004

POO POWER FOR A CHP PLANT

Messing about is costly when your business is power generation.  Alfagy's digester gas, biogas and sewage gas CHP (cogeneration) and generators are easy and space-saving to install.  In short, no reason to mess about - just 'plug and play' to generate heat and power!


Our engines use Lean Burn technology to achieve lowest NOx emissions and our effective noise protection is superior. Last year, we delivered 12 units that were so quiet that you could only hear their whisper at night at 35 dB(A).  Our Germanic manufacturing quality delivers high operational availability that out perform all competitors over years of operation.  This has been demonstrated over 35 years. 

 

Alfagy Digester Biogas CHP

Low BTU % Methane | Cogeneration | Genset | Onsite Power | Combined Heat and Power

Unit

kWe

kWt

Electric

Efficiency
(%)

Weight

(~tons)

Download
Data

Contact

Now

Alfagy B53

 53

78

33.2

3.2

Data Sheet

Contact

Alfagy N81

 81

128

32.6

3.2

Data Sheet

Contact

Alfagy B101

101

158

33.8

3.4

Data Sheet

Contact

Alfagy B115

115

133

37.0

3.75

Data Sheet

Contact

Alfagy B160

160

221

36.3

3.5

Data Sheet

Contact

Alfagy B185

185

207

37.9

4.3

Data Sheet

Contact

Alfagy B200

200

264 

36.4

4.3

Data Sheet

Contact

Alfagy B233

233

253

38.1

4.3

Data Sheet

Contact

Alfagy B250

250

260

41.4

4.3

Data Sheet

Contact

Alfagy B260

260

289

41.6

4.3

Data Sheet

Contact

Alfagy B300

300

403

36.9

5.4

Data Sheet

Contact

Alfagy B350

350

365

38.9

5.4

Data Sheet

Contact

Alfagy B400

400

456

40.2

5.5

Data Sheet

Contact

Alfagy B500

500

427

41.2

5.4

Data Sheet

Contact

Alfagy B600

600

608

42.5

11.6

Data Sheet

Contact

Alfagy B800

800

810

42.6

13.5

Data Sheet

Contact

Alfagy B1000

1000

1078 

41.2

9.0

Data Sheet

Contact

Alfagy B1200

1200

1255

42.0

14.0

Request

Contact

Alfagy B1572

1572

OR

39.2

 OR

Request

Contact

Alfagy B1750

1750

OR

39.5

 OR

Request

Contact

 Conversion rate depends on methane content and assumed to be 1/10 of the kW of gas consumed.

 Heat recovery: Heating water temperature: 90 °C outlet flow, max 70 °C return flow. 

 Rating Conditions: Combustion air/Ambient temperature 27 °C; rated altitude  max. 300 m;  methane content > 55%. 

 Exhaust gas emissions: NOx < 500 mg/Nm³ / CO < 1000 mg/Nm³. 

 Max HS: 200 ppm at 50% CH or 368 ppm at 100%  CH  or per m³ CH₄ the limit is 363 ppm or 550 mg H₂S/m³ CH₄.

Biogas, Digester gas and Sewage gas quality recommendations: Download Gas Data.
Carbon filter gas quality and parameters: Download Filter Data

 
http://www.alfagy.com/chp-combined-heat-and-power-cogeneration-get-a-quote-send-us-a-message
 
 